MV Transition Joints 3. JTM1 W(CS)

Products

3.24JTM1.240 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 20 ... 36 mm
  • Length: 1200 mm
  • Maximum outer diameter: 48.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3.24JTM1.300 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 1200 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3.24JTM1.400 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 24 ... 40 mm
  • Length: 1200 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 32.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3.24JTM1.95 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 18 ... 28 mm
  • Length: 1200 mm
  • Maximum outer diameter: 40.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

3.36JTM1.240 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 1400 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3.36JTM1.300 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 24 ... 42 mm
  • Length: 1400 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3.36JTM1.400 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 28 ... 46 mm
  • Length: 1400 mm
  • Maximum outer diameter: 60.0 mm
  • Minimum outer diameter: 38.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3.36JTM1.95 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 20 ... 32 mm
  • Length: 1300 mm
  • Maximum outer diameter: 44.0 mm
  • Minimum outer diameter: 30.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

3.42JTM1.240 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 26 ... 42 mm
  • Length: 1400 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 38.0 mm
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV

 

3.42JTM1.300 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 28 ... 46 mm
  • Length: 1400 mm
  • Maximum outer diameter: 60.0 mm
  • Minimum outer diameter: 40.0 mm
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV

 

3.42JTM1.400 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 32 ... 48 mm
  • Length: 1400 mm
  • Maximum outer diameter: 64.0 mm
  • Minimum outer diameter: 42.0 mm
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV

 

3.42JTM1.95 W(CS)

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 20 ... 34 mm
  • Length: 1300 mm
  • Maximum outer diameter: 50.0 mm
  • Minimum outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV

 

Description

Description

Standards

  • Test
    CENELEC HD 629.2; IEC 60055-1

Application

3. JTM1 heat-shrink transition joints are designed to connect single core plastic insulated cables with Cu wire or Cu tape screen and paper insulated PILC (HSL) armored/unarmored cables.

Technical characteristics

3. JTM is the NEW high performance, compact and easy to install joint.
A single body with all the electrical functions integrated!
The Nexans “TRIPLE GT125” is an integrated stress control field, insulating and conductive tube, which can withstand high voltage applications up to 24kV and up to 400mm².
From 36kV a double dual layer tube is used.
A double layer pad with conductive rubber inside and HK orange mastic outside ensure a Faraday cage and smooth the effect of the electrical field in the connector area.
MC types are supplied with GPH® mechanical connectors.
The outer sheath is restored with heavy/medium wall adhesive lined tubing.

Recommandations 3. JTM1 W(CS)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Protection
Polyammide based glue
Screen
Copper wires or tapes

Usage characteristics

Usage characteristics

Water sealing
Mastic

Resources

Resources

Selling & delivery Information

The range presented in this page is a broad picture of all the products. For more detailed information about product characteristics, please reach for your local customer service.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close