MV Straight Joints 17/24JTS1 KZ

Products

17JTS1.1000KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 630 ... 1000 mm²
  • Diameter over insulation, range: 34 ... 52 mm
  • Length: 1500 mm
  • Maximum outer diameter: 78.0 mm
  • Minimum outer diameter: 44.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.1200KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 800 ... 1200 mm²
  • Diameter over insulation, range: 38 ... 58 mm
  • Length: 1500 mm
  • Maximum outer diameter: 88.0 mm
  • Minimum outer diameter: 50.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.240KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 16 ... 32 mm
  • Length: 1000 mm
  • Maximum outer diameter: 50.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.300KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 18 ... 34 mm
  • Length: 1000 mm
  • Maximum outer diameter: 54.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.400KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 1000 mm
  • Maximum outer diameter: 58.0 mm
  • Minimum outer diameter: 30.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.630KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 400 ... 630 mm²
  • Diameter over insulation, range: 26 ... 44 mm
  • Length: 1000 mm
  • Maximum outer diameter: 64.0 mm
  • Minimum outer diameter: 38.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

17JTS1.95KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 12 ... 24 mm
  • Length: 1000 mm
  • Maximum outer diameter: 44.0 mm
  • Minimum outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

24JTS1.1000KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 630 ... 1000 mm²
  • Diameter over insulation, range: 36 ... 56 mm
  • Length: 1500 mm
  • Maximum outer diameter: 88.0 mm
  • Minimum outer diameter: 48.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.1200KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 800 ... 1200 mm²
  • Diameter over insulation, range: 40 ... 60 mm
  • Length: 1500 mm
  • Maximum outer diameter: 98.0 mm
  • Minimum outer diameter: 52.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.240KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 70 ... 240 mm²
  • Diameter over insulation, range: 20 ... 36 mm
  • Length: 1000 mm
  • Maximum outer diameter: 56.0 mm
  • Minimum outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.300KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 95 ... 300 mm²
  • Diameter over insulation, range: 22 ... 38 mm
  • Length: 1000 mm
  • Maximum outer diameter: 62.0 mm
  • Minimum outer diameter: 30.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.400KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 185 ... 400 mm²
  • Diameter over insulation, range: 24 ... 40 mm
  • Length: 1000 mm
  • Maximum outer diameter: 66.0 mm
  • Minimum outer diameter: 38.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.630KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 400 ... 630 mm²
  • Diameter over insulation, range: 30 ... 46 mm
  • Length: 1000 mm
  • Maximum outer diameter: 78.0 mm
  • Minimum outer diameter: 44.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

24JTS1.95KZ

Nexans ref.

  • Packaging: Unit
  • Conductor cross-section, range: 25 ... 95 mm²
  • Diameter over insulation, range: 18 ... 28 mm
  • Length: 1000 mm
  • Maximum outer diameter: 52.0 mm
  • Minimum outer diameter: 26.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

Description

Description

Standards

  • Product
    IEC 60502-4
  • Test
    CENELEC HD 629.1

Application

17/24JTS1 KZ heat-shrink straight joints are designed for armored, plastic insulated cables with Cu wire or Cu tape screen Armored (AWA/ATA), to accommodate either crimped or mechanical connectors.

Technical characteristics

17/24JTS KZ is the NEW high performance, compact and easy to install joint.
A single body with all the electrical functions integrated!
The Nexans “TRIPLE GT125” is an integrated stress control field, insulating and conductive tube, which can withstand high voltage applications up to 24kV and up to 400 mm² .
From 400 up to 1200 mm² a double dual layer tube is used.
A double layer pad with conductive rubber inside and HK orange mastic outside ensure a Faraday cage and smooth the effect of the electrical field in the connector area.
The electrical continuity of the screen (both Cu tape or Cu wire) is ensured with a standard tinned copper tape plus an earthing ferrule or braid.
Armor mechanical protection and electrical continuity is achieved by using a wraparound aluminum canister.

  • 17JTS type tested with BIL at 95 kV, PD at 2Uo (≤ 10 pC)
  • 24JTS type tested with BIL at 150 kV, PD at 2Uo (≤ 10 pC)

Recommandations JTS1 KZ

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Protection
Polyammide based glue
Screen
Copper wires or tapes

Usage characteristics

Usage characteristics

Water sealing
Mastic

Resources

Resources

Selling & delivery Information

The range presented in this page is a broad picture of all the products. For more detailed information about product characteristics, please reach for your local customer service.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close